Operating instructions ATEX - ifm

Operating instructions ATEX - ifm

14001470.03 07 / 2014 Operating instructions (Ex protection related part) for the submersible pressure transmitter PS3xxA according to the EU direc...

164KB Sizes 0 Downloads 23 Views

Recommend Documents

Operating instructions LINERECORDER SENSOR Version 4.2 - ifm
Functions of the limited environment: ○ Read parameters from device. ○ Edit parameters on the LR SENSOR surface (off

Operating instructions Ex protection related part Vibration sensor - ifm
I M1 (Group I, category M1, apparatus for mines susceptible to firedamp). Complies with the requirements of IEC 60079-0:

OPERATING INSTRUCTIONS
For consequential losses we do not assume del credere liability. For reasons of safety and CE it is not permitted to mod

Operating Instructions
... der Bildschirm nicht beschädigt wird, muss der Whiteboard-Löscher aus weichem ...... Trennzeichen. .... ist, verwe

Operating Instructions
To prevent fire or shock hazard, do not expose the unit to rain or moisture. To prevent fire, do not cover the ventilati

Operating Instructions
Put Mountfield 4-stroke, or an SAE 10W-30 oil, in the oil filler (Figure 5). Do not overfill, the oil tank capacity is.

Operating Instructions
The unit is not disconnected from the mains as long as ..... the main unit with the same or similar name as that ..... F

OPERATING INSTRUCTIONS
INPUT. OUTPUT. OPERATING INSTRUCTIONS. Unidare WMS Automatic and WMX Manual. Storage Heater Range. Model WMX/S706. Model

Operating Instructions
connect by wireless? connect by wired? connect via Wi-Fi Direct. See Wi-Fi Direct Guide in our website. (http://www.rico

Additional Instructions BVS 13 ATEX E104X BVS 13 ATEX - Burkert
10. Particularsafetyinstructions. BVS 13 ATEX E104X / E087X. 4.2. Installation locking wire for PE99 and PX03. DAN

14001470.03

07 / 2014

Operating instructions (Ex protection related part) for the submersible pressure transmitter PS3xxA according to the EU directive 94/9/EC Annex VIII (ATEX) group II, equipment category 1D / 1G

UK

Remarks for safe use in hazardous areas Functions and features • Use in hazardous areas according to the classification I M1 (Group I, category M1, apparatus for mines susceptible to firedamp). • Use in hazardous areas according to the classification II 1G, II 1/2G, II 2G (Group II, category II 1G, II 1/2G, II 2G, apparatus for gas atmosphere). • Use in hazardous areas according to the classification II 1D (Group II, category II 1D, apparatus for dust atmosphere). EC type test certificate BVS 10 ATEX E 132 X IECEx BVS 10.0085 X • Marking I M1 Ex ia I Ma II 1 G Ex ia IIA T4/T5/T6 Ga II 1/2G Ex ia IIC T4/T5/T6 Ga/Gb II 2 G Ex ia IIC T4/T5/T6 Gb II 1D Ex ia IIIC T120°C Da Installation / Set-up The units must only be installed, connected and set up by qualified staff. The qualified staff must have knowledge of protection classes, regulations and provisions for apparatus in hazardous areas. Check whether the classification (see "Marking" above and marking on the unit) is suitable for the application.

2

• Connection to intrinsically safe supply isolators (Ex ia). • Safety-related maximum values Voltage Ui Current intensity Ii Power Pi Maximum effective internal capacitance (Ci) Maximum effective internal inductance (Li)

30 V DC 100 mA 1 W for groups I and II 750 / 650 / 550 mW for group III 16.5 nF +0.1 nF/m cable (value see type label on the submersible pressure UK transmitter) 0 μH +1 μH/m cable (value see type label on the submersible pressure transmitter)

• Permissible ambient and medium temperature at the mounting location (proper usage) ATEX category Ambient and medium temperature T6: -10 ... +60 °C M 1, 1 G, 1/2 G, 2 G T5: -10 ... +80 °C (Ma, Ga, Ga/Gb, Gb) T4: -10 ... +85 °C -10 ... +40 °C (750 mW) 1 D, 1/2 D, 2 D -10 ... +70 °C (650 mW) (Da, Da/Db, Db) -10 ... +85 °C (550 mW) Installation remarks / Installation • Adhere to the respective national regulations and provisions as well as the relevant installation regulations. • Avoid electrostatic charging on connection cables. • Prepare the cable with ferrules. • The cable screen is conductively connected to the housing. • Ground the cable screen on at least one cable side if the cables are longer than 30 m (2 wires) or leave the building. • Ensure that no moisture penetrates at the end of the cable. • Protect units and cables against damage. • For the connections and the electrical characteristics please see the unit marking or the technical data sheet. Special conditions for safe operation • The unit is suitable for installation through walls which separate zone 0 from zone 1 or zone 20 from zone 21. • If it is installed through a zone-separating wall, the following protection rating to IEC 60529 must be ensured: -- IP 67 for zone 0 / zone 1 -- IP 6X for zone 20 / zone 21.

3

• For the cable pass-through in the zone-separating wall the following protection rating to IEC 60529 must be ensured: -- IP 67 for zone 0 / zone 1 -- IP 6X for zone 20 / zone 21. Integrate an overvoltage protection if the mounting position is less than 1 m away from the transition into zone 0. • When the submersible pressure transmitter is installed in zone 0 / zone 1 the screen of the connection cable and the metal part of the optional tension clamp must be included in the equalisation of potential of the tank. • The manufacturer's indications concerning the use of the submersible pressure transmitter in combination with aggressive / corrosive media and the risk by mechanical impact must be taken into account. Maintenance / Repair • The submersible pressure transmitter has to be included in the recurrent pressure test of the tank. • The unit must not be modified nor can it be repaired. In case of a fault please contact the manufacturer. • If required, the technical data sheets and EC declarations of conformity can be obtained from the manufacturer. Indicate the article number.

4