SATRON VT Pressure Transmitter

SATRON VT Pressure Transmitter

BPV710 M2, revision 3 01.01.2014 SATRON VT Pressure Transmitter SATRON VT pressure transmitter belongs to the series V-transmitters. SATRON VT is us...

706KB Sizes 1 Downloads 10 Views

BPV710

M2, revision 3 01.01.2014

SATRON VT Pressure Transmitter SATRON VT pressure transmitter belongs to the series V-transmitters. SATRON VT is used for 0-1.4 kPa...0-100 MPa ranges. It is a 2-wire transmitter with HART® standard communication. In pressure measuring applications SATRON VT-transmitters are used for measuring the pressure of clean gases, steam and noncrystallizing liquids.The transmitter's sensor is piezoresistive. The rangeability is 100:1 for types VT6 - VT8.

TECHNICAL SPECIFICATIONS max.span ) ]% of calibrated span

Measuring range and span See Selection Chart.

±[0.025+0.01 x (

Zero and Span adjustment Zero elevation: Calibrated span is freely selectable on the specified range depending from the desired option. This can be made by using extern control shafts, keyboard (display option), HART®275/375 communicator.

(incl. nonlinearity, hysteresis and repeatability)

Temperature limits Ambient: -30 to +80 °C Process: -30 to +120 °C, DIN 16288 -20 to +200 °C, DIN 3852-X Shipping and storage: -40 to +80 °C. Operating temperature of display: 0 to +50ºC (does not affect operation of the transmitter) Pressure limits Min. and max. process pressure: See the appended tables. Volumetric displacement < 0.5 mm3 /max. span Output 2-wire (2W), 4-20 mA, user selectable for linear, square root, inverted signal or the transfer function (16 points)specified by the user Supply voltage and permissible load See the load capacity diagram; 4-20 mA output: 12-35 VDC. Humidity limits 0-100 % RH; freezing of condensed water not allowed in reference pressure channels.

Long-term stability ±0.1 %/max. span/12 months Temperature effect on compensated temperature ranges -20...+80 °C Zero and span shift: ±0.15 % of max. span 0 to +200 °C, (process connection, code 3, DIN3852-X-G½A, Flush Mounted) ±1 % of max. span, VT6 - VT7 ±2 % of max. span, VT4 - VT5 Mounting position effect (VT3 - VT7) Zero error < 0.32 kPa, which can be calibrated out. VT8: mounting position has no effect

Accuracy ±0.05 % of calibrated span (span 1:1-5:1 /max.range). On the measuring ranges 5:1-100:1:

Enclosure class IP66 Housing with PLUG connector, housing type codes H and T Housing: AISI316, Seals: Viton® and NBR TEST jacks: MS358Sn/PVDF, protected with silicone rubber shield. PLUG connector: PA6-GF30 jacket, Silicone rubber seal, AISI316 retaining screw. Housing with junction box/terminal strip, housing type codes M and N Housing: AISI303/316, Seals: Nitrile and Viton®; Nameplates: Polyester Connection hose between sensing element and housing : Codes L and K : PTFE hose with AISI316 braiding. Load / Ω

Vibration effect (IEC 68-2-6: FC): ±0.1 % of measuring range/ 2g/10 to 2000 Hz 4g/10 to 100 Hz

Imax = 20.5mA

Power supply effect < ±0.01 of calibrated span per volt Insulation test voltage 500 V rms 50 Hz

Supply voltage / V

CONSTRUCTION AND CALIBRATION Materials Diaphragm 1): AISI316L (EN 1.4435), Duplex (EN 1.4462), Hast. C276 (EN 2.4819), Tantalum or Titanium Gr2 (EN 3.7035). 1)

PERFORMANCE SPECIFICATIONS Tested in accordance with IEC 60770: Reference conditions, specified span, no range elevation, horizontal mounting; AISI316L diaphragm, silicone oil fill.

Filling fluid: Silicone oil or inert oil (VT3 - VT7)

Imin = 3.7mA

Damping Time constant is continuously adjustable 0.01 to 60 s.

calibrated span

Other sensing element materials: AISI316, SIS 2343.

Rmax = Supply voltage - 10V Imax Imax = 20.5mA using HART®-communication Imax = 23mA (when the alarm current 22.5mA is on)

Parts in contact with process medium

Supply voltage for transmitter without intrinsic safety (not ATEX)

Pressure limits

Minimum process pressure

Maximum process pressure, MPa Transmitter type VT3 VT4 VT5 VT6 VT7 VT8

Max. overload pressure

Pressure class

0.2 0.3 1.5 7.5 40.0 100.0

PN40 PN40 PN40 PN100 PN250 PN1000

(VT8: no min. pressure limitations) Tproc. °C 20 40 80 120

Minimum pressure for different fill fluids (kPa, abs.) DC200 100 cSt 5 8 16 21

Satron Instruments Inc., P.O.Box 22, FI-33901 Tampere, Finland Tel. +358 207 464 800, Telefax +358 207 464 801, www.satron.com

Inert oil 8 10 28 53

BPV710

SATRON VT Pressure Transmitter Calibration For customer-specified range with 1 s. damping. (If range is not specified, transmitter is calibrated for maximum range.) Electrical connections Housing with PLUG connector, H and T: PLUG connector, connector type DIN 43650 model AF; Pg9 gland for cable; wire cross-section 0.5 to 1.5 mm2. Housing with junction box/terminal strip, M and N: M20x1.5, 1/2-NPT inlet; screw terminals for 0.5 to 2.5 mm2 wires

Weight Transmitter - with housing types H and T - with housing type M and N

: 0,7 kg : 1.2 kg

01.01.2014 Special Conditions for Safe Use (X) : The enclosure with plastic window and the plastic DIN43650 connector must not be installed in potentially explosive atmosphere requiring category 1 apparatus. The non-conducting surface of the sensor element may be charged by the flow of non-conducting media, so there may be electrostatic hazard with IIC-gases. These units should be marked 2 GD. The equipment shall be installed and connected according to the manufacturers instructions.

Load / Ω

Product Certifications European Directive Information Electro Magnetic Compatibility (EMC directive 2004/108/EC) All pressure transmitters

Atex Directive (94/9/EC) Satron Instruments Inc. complies with the ATEX Directive. European Pressure Equipment Directive (PED) (97/23/EC) All Pressure Transmitters : - Sound Engineering Practice

Supply voltage / V Rmax = Supply voltage - 10V Imax Imax = 20.5mA using HART®-communication Imax = 23mA (when the alarm current 22.5mA is

Transmitters with nominal pressure higher than 200 bar fulfil the requirements of the Conformity Assessment procedure Module A of the directive.

Supply voltage for transmitter with certified intrinsic safety (ATEX)

Hazardous Locations Certifications European Certifications ATEX Intrinsic Safety Certification No. : DNV-2007-OSL-ATEX- 1346X II 1 GD T135°C EEx ia II C T4 -20°C ≤ Tamb ≤ 50°C II 2 GD T135°C EEx ia II C T4 -20°C ≤ Tamb ≤ 50°C

Input Parameters : Ui = 28 V Ii = 93 mA Pi = 0.651 W Ci = 5 nF Li = 0.2 mH

Wiring Housing with PLUG connector, codes H and T

BPV710

SATRON VT Pressure Transmitter

01.01.2014

Ø48

165 VT3 ...VT7, ATEX +15 145 VT8, ATEX +15

Pg 9 std. housing codes H and T

75

Ø48

165 VT3 ...VT7, ATEX +15 145 VT8, ATEX +15

M20 x 1,5 std. housing code M

70

195 VT3 ...VT7, ATEX +15 175 VT8, ATEX +15

M20 x 1,5 std. housing code N

G½ A DIN 16288

Dimensions ( in mm)

Hex 36 VT3 ... VT7 Hex 27 VT8

BPV710

SATRON VT Pressure Transmitter 195 VT3 ...VT7, ATEX +15 175 VT8, ATEX +15

G½ A DIN 16288

Dimensions ( in mm)

01.01.2014

91

Hex 36 VT3 ... VT7 Hex 27 VT8

14

Ø27

Ø26

Hex 27

G½ Ø30

Housing codes H, T and M 195 Housing code N 225 Atex transmitter code 1, +15

DIN3852-E-G½

PG9 housing N with plug DIN 43650, code N_ / P

2,5 18,5

VT4 - VT7 Threaded DIN3852-X-G½A Flush-Mounted Diaphragm

Process coupling DIN 3852-X-G½

Wiring Wiring Wiring Housing with terminal strip, code M

Housing with terminal strip and display, code N

Housing with terminal strip and display with plug connector DIN 43650 , code N _/ _P

BPV710

SATRON VT Pressure Transmitter

01.01.2014

Clearance for cover removal

100

Housing codes H, T and M 215 Housing code N 245 Atex transmitter code 1, +15

170

Dimensions (mm)

Option K

125

110

149

min. R75

60

Option L

Pg9 std. housing type H and T M20x1.5 std. housing types M and N

Remote electronics, connecting cable with protection hose, codes L and K

min. 290

Use of selector switch : RUN = working position PZ = Process value zero D = Damping adjustment S = Span adjustment Z = Zero adjustment DN = Down UP = Up

Housing with PLUG connector, code T Process temperature /°C

Keyboard : Esc

= = =

Enter

=

Press Esc move back towards the top of the main menu. Use the UP arrow key to move up on the current menu level or to increase the selected parameter value. Use the DOWN arrow key to move down on the current menu level or to decrease the selected parameter value. Press ENTER to move to a lower level in a menu or to accept a command or parameter value.

Recommended application range (horizontal mounting)

Ambient temperature /°C Housing with display, code N

Process temperature limits for the transmitter of high temperature, process connection, code 3 (DIN3852-X-G1/2A, Flush mounted)

BPV710

SATRON VT Pressure Transmitter

01.01.2014

Selection Chart Adjustability VT3 VT4 VT5 VTA5 VT6 VTA6 VT7 VT8

Span, min 1.4 kPa (14 mbar) 4 kPa (40 mbar) 10 kPa (100 mbar) 10 kPa (100 mbar) 0.03 MPa (0.3 bar) 0.03 MPa (0.3 bar) 0.15 MPa (1.5 bar) 1 MPa (10 bar)

Output

S 4-20mA DC/HART®

Span, max 35 kPa (350 mbar) 100 kPa (1000 mbar) 500 kPa (5000 mbar) 500 kPa (5000 mbar) 3 MPa (30bar) 3 MPa (30 bar) 15 MPa (150 bar) 100 MPa (1000 bar) -protocol

Process connection 1 G 1/2A DIN 16288 (male) Wetted material

Measuring range -35...+35 kPa (-350...350 mbar) -100...+100 kPa (-1000...1000 mbar) -100...+500 kPa (-1000...5000 mbar) 0...+500 kPa (0...5000 mbar), abs. -0.1...+3 MPa (-1...+30 bar) 0...+3 MPa (0...+30 bar), abs. 0...+15 MPa (0...+150 bar), abs. -0.1...+100 MPa (-1...+1000 bar)

Body Code 2 3 6 8

2

3

1/2-NPT (male)

Diaphragm Code Material 2 AISI316L (EN 1.4435) (no VT8) 3 Hast. C276 (EN 2.4819) (no VT3, VT8) 5 Tantalum (no VT3, VT8) (*) 6 Titanium Gr2 (EN 3.7035) (no VT3, VT4) (*) 8 Duplex (EN 1.4462) (no VT3, VT8)

Material AISI316L (EN 1.4404) Hast. C 276 (EN 2.4819) Titanium Gr2 (EN 3.7035) Duplex (EN 1.4462)

Fill fluid (specify for types VT3 - VT7)

S

DIN 3852-X-G½A (male), Flush Mounted, not VT3, VT8

G Inert oil

Silicone oil

Housing type H Housing with PLUG-connector, DIN43650, no display, inlet PG9 T Housing with PLUG-connector and with manual adjust, DIN43650, no display, inlet PG9, (no ATEX) M Housing with junction box/terminal strip, no display, inlet M20x1,5 N Housing with junction box/terminal strip, with display, inlet M20x1,5 Explosion proof 0 No explosion proof classification

1 Atex Intrinsic Safety,

II 1 GD T135°C (**)

Process coupling 0 No coupling 1 Threaded coupling G½, DIN 16288 2 Threaded coupling G½, DIN 3852-X-G½ (Flush-Mounted)

Special size of electrical inlet N 1/2 NPT G Pg13.5

P

Plug DIN 43650

Special features Remote electronics (specify only if housing connected with cable to sensing element) - connecting cable with protection hose L Hose protected with PTFE/AISI316 braiding, straight K Hose protected with PTFE/AISI316 braiding, angle of 90° Length of connection cable between sensing element and housing 2 2 m cable 3 3 m cable etc. (max. 10 meter) Mounting parts for remote electronics for Ø 51 mm tube 0 No mounting parts 1 Mounting parts Documentation Calibration certificate AE English

Installation and operating instructions I E

English

IF

Finnish

Material certificates O No material certificate MC1 Raw material certificate without appendices, in accordance with SFS-EN 10204-2.1 (DIN 50049-2.1) standard MC2 Raw material certificate for wetted parts, in accordance with SFS-EN 10204-2.2 (DIN 50049-2.2) standard MC3 Raw material certificate for wetted parts, in accordance with SFS-EN 10204-3.1 B (DIN 50049-3.1 B) standard We reserve the right for technical modifications without prior notice. HART® is a registered trademark of HART Communication Foundation. Viton® is the registered trademark of DuPont Down Elastomers. Hastelloy® is the registered trademark of Haynes International. Teflon® is the registered trademark of E.I. du Pont de Nemours & Co

(*) = not for process connection code 3

II 2 GD T135°C (**) = Housing H and N : ATEX transmitter with display are the model without membrane key.